Logo image
A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis
Journal article   Open access   Peer reviewed

A retrospective observational study evaluating the safety and effectiveness of commercially available automated insulin delivery systems in people with type 1 diabetes and gastroparesis

Rachael J. L. Tan, Anusha Ahuja, Aakanksha Shrestha, Geraldine Gallen, Ben Stotesbury, Yee Cheah, Omar G Mustafa, Martin Brunel Whyte, Jonathan Croos, Adam Shooshtarian, …
Diabetes, obesity & metabolism, Vol.28(5), pp.3933-3942
01/05/2026
PMID: 41713943

Abstract

automated insulin delivery CGM gastroparesis hybrid closed loop type 1 diabetes mellitus

Aims: A retrospective observational cohort study evaluating real-world outcomes in adults with type 1 diabetes and gastroparesis using automated hybrid closed loop insulin delivery systems (HCL).

Materials and methods: All adults with type 1 diabetes and gastroparesis attending King's College Hospital diabetes service and using continuous glucose monitoring (CGM) from 5 October 2023 to 16 January 2025 were included. Glycaemic data (HbA1c, CGM metrics), hypoglycaemia awareness (Gold score), diabetes distress (DDS2), and acute complications (DKA, severe hypoglycaemia) were collected from electronic health records and glucose platforms for 12 months pre- and post-HCL initiation.

Results: From 1827 clinic attendees, 36 adults with gastroparesis were identified, with 17 initiating HCL. HCL and non-HCL groups had comparable baseline characteristics and metrics (HCL: Mean(SD) HbA1c 70(21)mmol/mol [8.6(1.9)%]; Time in range (TIR) 36.8 (21.9) % vs. non-HCL: HbA1c 71 (25) mmol/mol [8.6(2.3)%]; TIR 37.1(19.2)%, p = 0.73). Post-HCL, HbA1c median(IQR) fell to 57(52.5-65.0) mmol/mol [7.4(7.0-8.1)%] (p < 0.001). TIR increased to 55.7(19.9)% (p < 0.001), with a significant reduction in Time above range Level 2 (TAR2) [>13.9 mmol/L/>250 mg/dL](32.7% to 14.5%, p = 0.014). Gold score improved (2.5 to 1.5, p = 0.019), but DDS2 remained unchanged. No increase in DKA or severe hypoglycaemia occurred.

Conclusions: Within a specialist multidisciplinary team setting, HCL systems significantly reduce HbA1c without increasing risk of severe hypoglycaemia or DKA in people with type 1 diabetes and gastroparesis.

url
https://doi.org/10.1111/dom.70575View
Published (Version of record)

Metrics

1 Record Views

Details

Logo image

Usage Policy