Abstract
Sealing of the cavity formed between a rotating disc and a stator with an asymmetric external flow is considered. In these circumstances circumferential pressure variations in the external flow and the pumping action of the disc may draw fluid into the cavity. Gas concentration measurements, showing this effect, have been obtained from a model experiment with a simple axial clearance seal. In the experiment, guide vanes, fitted upstream of the rim seal, generate an asymmetric external flow. The measurements are shown to be in reasonable agreement with three-dimensional computational fluid dynamics (CFD) calculations and are also compared with more elementary models. The CFD results give further insight into the effects of ingestion within the cavity.