Abstract
An experimental investigation of heat exchange in a three-phase direct contact condenser was carried out using a 70-cm-high Perspex tube with a 4-cm inner diameter. The active direct contact condenser comprised 48 cm. Pentane vapour at three initial temperatures (40℃,43.5℃, and 47.5℃) and water at a constant temperature (19℃) were used as the dispersed and continuous phases, respectively, with different mass flow rate ratios. The results showed that the continuous phase outlet temperature increased with increasing mass flow rate ratio. On the contrary, the continuous phase temperature decreased with increases in the continuous mass flow rate. The initial temperature of the dispersed phase slightly affected the direct contact condenser output, which confirms a latent phase effect in this type of heat exchanger.