Logo image
Open Research University homepage
Surrey researchers Sign in
Retrofitting an environmental monitor with a silicon photomultiplier sensor
Journal article   Open access   Peer reviewed

Retrofitting an environmental monitor with a silicon photomultiplier sensor

Mohammed Alharbi, Peter H. Burgess, Matt Taggart and Paul J. Sellin
Journal of Radiological Protection
14/05/2020

Abstract

Radiation monitoring; silicon photomultiplier; alpha beta discrimination
We report on the retrofitting of a standard DP2 environmental radiation monitor replacing the photomultiplier tube with a silicon photomultiplier (SiPM). The use of a SiPM has several advantages for a hand-held radiation monitor, including convenient low voltage operation and physical robustness. The SiPM is used to replace the existing photomultiplier tube, and we report the detection efficiency and alpha/beta discrimination performance of the modified probe compared to an unmodified version.
pdf
Alharbi+et+al_2020_J._Radiol._Prot._10.1088_1361-6498_ab9312876.18 kBDownloadView
TextCC BY V4.0 Open Access
url
http://dx.doi.org/10.1088/1361-6498/ab9312View
Published (Version of record)

Metrics

Details

Logo image