Logo image
Decay spectroscopy of Tb 152 : A diagnostic component of the terbium theragnostic toolbox
Journal article   Peer reviewed

Decay spectroscopy of Tb 152 : A diagnostic component of the terbium theragnostic toolbox

E. B. O'Sullivan, S. M. Collins, J.-M. Daugas, L. Domenichetti, J. Heery, J. Henderson, U. Köster, C. Michelagnoli, T. Parry, S. Pascu, …
Physical review. C, Vol.114(5), 054301
11/2026

Abstract

Terbium-152, decaying by electron capture and beta + emission to the ground and excited states in 152Gd, shows potential for use in PET imaging as part of personalized cancer treatments. We report results of decay spectroscopy measurements, providing nuclear data necessary for medical use of this radionuclide. Sources of 152Tb were prepared at CERN-ISOLDE by proton-induced spallation of a tantalum target, followed by on-line mass separation. The decay of these sources was measured at ILL Grenoble using the gamma -ray coincidence spectrometer FIPPS and the PN1 electron-gamma coincidence spectroscopy setup. We present an updated level scheme for the decay, comprising 751 gamma -ray transitions placed to 200 excited states. Angular correlation analysis and conversion-electron spectroscopy provide spin-parity assignments to levels, multipolarity assignments to gamma rays, and measurements of electric monopole transition strengths. A transition intensity balance of the resulting level scheme provides beta feeding intensities for each level, showing an 8.9% reduction in the positron emission probability and an increase of 4.5% in the gamma -ray energy emitted per decay compared to the existing evaluated data for this decay.

Metrics

1 Record Views

Details

Logo image

Usage Policy