Are different consumer sleep technologies measuring the same essential aspects of sleep?
Journal article   Open access   Peer reviewed

Are different consumer sleep technologies measuring the same essential aspects of sleep?

Kiran K G Ravindran, Ciro Della Monica, Giuseppe Atzori, Marta Messina Pineda, Ramin Nilforooshan, Hana Hassanin, Victoria Louise Revell and Derk-Jan Dijk
Sleep, zsag231
22/08/2026

Abstract

Evaluation 03​ Good Health & Well-being consumer sleep technology dementia polysomnography sleep stages aged sleep sleep diary Sleep Studies
Study objectives Consumer sleep technologies (CSTs) enable low-burden longitudinal sleep monitoring, and their measures are often interpreted as equivalent to polysomnography (PSG) measures. We applied measurement reliability-aware approaches to determine whether CST-derived ‘sleep’ measures (1) are interchangeable or device-specific, (2) can reliably assess participant-level sleep characteristics and (3) converge onto interpretable principal components representing essential aspects of sleep. Methods Data from 74 older adults (20 people living with dementia) were collected at-home (total=752 paired nights) using four modalities simultaneously: research-grade actigraphy (Axivity), a wearable (Withings Watch), a nearable (Withings Sleep Analyser) and Sleep Diary, followed by one in-lab PSG assessment. We applied Bland-Altman analyses, repeated-measures correlation analyses, intraclass correlation coefficients (ICC) and principal component analysis (PCA). Results Single-night between-device correlations and correlations with PSG were weak (r<0.3) for most measures but moderate (0.3≤r<0.7) for duration- and timing measures. Bland-Altman analyses revealed systematic disagreement with PSG, with total sleep time and sleep efficiency overestimated, wake after sleep onset underestimated, and poor agreement for sleep-stage durations. The number of nights required to obtain acceptable reliability (ICC≥0.7) varied across measures, modalities and participant groups, with 71% of measures reaching an ICC ≥0.7 within seven nights. Reliability-filtered PCA yielded interpretable principal components, with Duration being the only sleep aspect showing consistent moderate between-device associations. Conclusions Correlation of most sleep measures across assessment modalities is poor, suggesting that the consumer sleep technologies tested in our study may not measure the same essential aspects of sleep. Duration was the only sleep aspect transferable between these devices.
pdf
SLEEP-2026-0381.R2_Proof_fl_Accepted8.86 MBDownloadView
Open Access CC BY V4.0

Metrics

1 Record Views

Details

Logo image

Usage Policy